Extensive line up product for AC and DC measurement.
Our Electronic Digital LCD Meter have Three model line up based on the easy to read and features high preformance. AC and DC digital meter are intended for measuring, monitoring energy-saving and preventive maintenance for all electric power network.
Not only JIS standard 110mm size, we are proud to be the first brand who has DIN 72mm saving space type in Japan market. With open network, communication output or analog output, pulse output and alarm output are avaible as external outputs, necessary for remote mornitoring system.
Please select a product according to your electrical networks.
Type name | SQLC-110L | SFLC-110L | SALC-110L | SVLC-110L | SMLC-110L | SQLC-72L | ||
---|---|---|---|---|---|---|---|---|
Measurement item | Voltage | - | ||||||
Current | - | - | ||||||
Demand Current | - | - | ||||||
Active Power | - | - | - | |||||
Demand Power | - | - | - | |||||
Reactive Power | - | - | - | |||||
Apparent Power | (3P4W only) | - | - | - | - | |||
Power Factor | - | - | - | |||||
Frequency | - | |||||||
Earth Leakage | - | - | - | - | ||||
Active Energy | - | - | - | |||||
Reavtive Energy | - | - | - | |||||
Harmonic Current | - | - | - | - | - | |||
Harmonic Voltage | - | - | - | - | - | |||
Zero-phase Voltage | - | - | - | - | - | |||
Output Item | Analog *1 | 4 contacts | 3 contacts | 3 contacts | 3 contacts | 4 contacts | - | |
Pulse | 2 contacts *2 | 1 contact | - | - | - | 2 contacts *3 | ||
Alarm | 2 contacts *2 | 1 contact | 1 contact | 1 contact | 2 contacts | 2 contacts *3 | ||
CPU Error | 1 contact *2 | - | - | - | - | - | ||
Communication *1 | MODBUS | - | - | |||||
CC-Link | - | - | - | - | ||||
Protocol A | - | - | - | - | ||||
Anywire | - | - | - | - | - | |||
External Operation Input | 2 contacts | 1 contact | 1 contact | 1 contact | 2 contacts | 1 contact | ||
CE Marking | Support | - | - | - | - | Support | ||
Wide range CT | Support | - | - | - | - | - | ||
400Hz Frequency Input | Support | - | - | - | - | - | ||
440V Directly Input | Support | - | - | - | - | Support | ||
Setting Function by PC | - | - | - | - | - | |||
Language Display | Japanese / English *4 |
Japanese / English *4 |
Japanese / English *4 |
Japanese / English *4 |
Japanese / English *4 |
English | ||
|
||||||||
*1 Please select either Analog Output or Communication Output. |
Type name | XLC-110 XLC-110L |
TLC-110 TLC-110L |
MRLC-110 | ||
---|---|---|---|---|---|
Input Circuit | Max. 3 | Max. 3 | Max. 3 | ||
Function of Receiving Meter | |||||
Measurement item | Voltage | - | |||
Current | - | ||||
Active Power | - | ||||
Active Energy | - | ||||
Output Item | Analog *1 | 3 contacts | 3 contacts | - | |
Alarm | - | - | 6 contacts *2 | ||
Pulse | - | 1 contact | - | ||
Communication *1 | MODBUS | - | |||
Protocol A | |||||
External Operation Input | 1 contact | 1 contact | 1 contact | ||
Setting Function by USB | - | - | - | ||
Language Display | Japanese | Japanese | English | ||
|
|||||
*1 Please specify either analog output or communication output. |
Type | Hard model | Input circuit | Output specification | Catalogue | Instruction Manual | Communication specification |
---|---|---|---|---|---|---|
SQLC-110L | D Phase display:R-S-T-N Display language: Japanese |
1φ2W 1φ3W 3φ3W Shared (3φ3W 2VT2CT) |
No output / Analog output | - | ||
Modbus RTU | * | * | ||||
CC-Link | * | * | ||||
Protocol A | * | * | ||||
Anywire | * | * | ||||
3φ4W | No output / Analog output | * | - | |||
Modbus RTU | * | * | ||||
CC-Link | * | * | ||||
Protocol A | * | * | ||||
Anywire | * | * | ||||
3φ3W 2VT3CT |
No output / Analog output | * | - | |||
Modbus RTU | * | * | ||||
CC-Link | * | * | ||||
Protocol A | * | * | ||||
Anywire | * | * | ||||
E Phase display:R-Y-B-W Display language: English |
1φ2W 1φ3W 3φ3W Shared (3φ3W 2VT2CT) |
No output / Analog output | - | |||
Modbus RTU | ||||||
3φ4W | No output / Analog output | - | ||||
Modbus RTU | ||||||
3φ3W 2VT3CT |
No output / Analog output | - | ||||
F Phase display:U-V-W-N Display language: English |
1φ2W 1φ3W 3φ3W Shared (3φ3W 2VT2CT) |
No output / Analog output | - | |||
CC-Link | ||||||
G Phase display:L1-L2-L3-N Display language: English |
1φ2W 1φ3W 3φ3W Shared (3φ3W 2VT2CT) |
No output / Analog output | - | |||
3φ4W | No output / Analog output | - | ||||
Modbus RTU |
Type | Hard model | Input circuit | Output specification | Catalogue | Instruction Manual | Communication specification |
---|---|---|---|---|---|---|
SQLC-110L | D Phase display:R-S-T-N Display language: Japanese |
1φ2W 1φ3W 3φ3W Shared / 1φ2W / 1φ3W / 3φ3W |
No output / Analog output | * | * | - |
Type | Hard model | Input circuit | Output specification | Catalogue | Instruction Manual | Communication specification |
---|---|---|---|---|---|---|
SQLC-110L | D Phase display:R-S-T-N Display language: Japanese |
3φ3W Wide range CT |
No output / Analog output | * | * | - |
E Phase display:R-Y-B-W Display language: English |
* | - | ||||
F Phase display:U-V-W-N Display language: English |
* | - | ||||
G Phase display:L1-L2-L3-N Display language: English |
* | - |
*This website does not disclose instruction manual and communication specification for all model released. If you cannot find the instruction manual that you want, please contact the dealer from which you purchase the product or use our. Inquiry Form to make request.
*This website does not disclose instruction manual and communication specification for all model released. If you cannot find the instruction manual that you want, please contact the dealer from which you purchase the product or use our. Inquiry Form to make request.
*This website does not disclose instruction manual and communication specification for all model released. If you cannot find the instruction manual that you want, please contact the dealer from which you purchase the product or use our. Inquiry Form to make request.
*This website does not disclose instruction manual and communication specification for all model released. If you cannot find the instruction manual that you want, please contact the dealer from which you purchase the product or use our. Inquiry Form to make request.
*This website does not disclose instruction manual and communication specification for all model released. If you cannot find the instruction manual that you want, please contact the dealer from which you purchase the product or use our. Inquiry Form to make request.
Type | Output specification | Catalogue | Instruction Manual | Communication specification |
---|---|---|---|---|
XLC-110 XLC-110L |
No output / Analog output | - | ||
Modbus RTU | TBA | * | ||
Protocol A | * |
*This website does not disclose instruction manual and communication specification for all model released. If you cannot find the instruction manual that you want, please contact the dealer from which you purchase the product or use our. Inquiry Form to make request.
Type | Output specification | Catalogue | Instruction Manual | Communication specification |
---|---|---|---|---|
TLC-110 TLC-110L |
No output / Analog output | - | ||
Modbus RTU | TBA | * | ||
Protocol A | * |
*This website does not disclose instruction manual and communication specification for all model released. If you cannot find the instruction manual that you want, please contact the dealer from which you purchase the product or use our. Inquiry Form to make request.
Type | Communication Output | Catalogue | Instruction Manual | Communication specification |
---|---|---|---|---|
MRLC-110 | No output | * | - | |
Protocol A | * | * |
*This website does not disclose instruction manual and communication specification for all model released. If you cannot find the instruction manual that you want, please contact the dealer from which you purchase the product or use our. Inquiry Form to make request.