isolator |
|
|
|
|
|
FWTT |
|
|
|
|
|
Convert to compatible signal among systems by insulating various kinds of DC signals. As insulated 2 outputs can be extracted, controlling/ monitoring are possible with 1 unit. response time : 0.1s or less/90%
|
high speed isolator |
|
|
|
|
|
FWHS |
|
|
|
|
|
Convert to compatible signal among systems by insulating various kinds of DC signals. As insulated 2 outputs can be extracted, controlling/ monitoring are possible with 1 unit. response time : 500μs or less/90%
|
super high speed isolator |
|
|
|
|
|
FWUS |
|
|
|
|
|
Convert to compatible signal among systems by insulating various kinds
of DC signals. As insulated 2 outputs can be extracted, controlling/ monitoring are possible
with 1 unit. response time : 180μs or less/90%
|
current loop supply (distributor) |
|
|
|
|
|
FWDT |
|
|
|
|
|
Supplying power source to 2-wire system transmitter, receiving DC4-20mA signal from transmitter and outputting insulated proportional DC signal. As insulated 2 outputs can be extracted, controlling/ monitoring are possible with 1 unit.
|
thermocouple transducer |
|
|
|
|
|
FWHT |
|
|
|
|
|
Insulating input/ output and converting to DC signals in proportion to temperature with thermoelectromotive force of various kinds of thermocouple as input. As insulated 2 outputs can be extracted, controlling/ monitoring are possible with 1 unit.
|
resistance temperature transducer |
|
|
|
|
|
FWRH |
|
|
|
|
|
Insulating input/ output and converting to DC signals in proportion to temperature with resistance value of 3-wire system resistance temperature element as input. As insulated 2 outputs can be extracted, controlling/ monitoring are possible with 1 unit.
|
potentiometer transducer |
|
|
|
|
|
FWRT |
|
|
|
|
|
By replacing mechanical angle and position displacement to resistance change of potentiometer as input and convert to DC signals in proportion to displacement by insulation. As insulated 2 outputs can be extracted, controlling/ monitoring are possible with 1 unit.
|
revolution speed transducer |
|
|
|
|
|
FWGT |
|
|
|
|
|
With tachogenerator mounted to generator, etc. as input and convert to DC signals in proportion to revolution speed(frequency) by insulating between input and output. As insulated 2 outputs can be extracted, controlling/ monitoring are possible with 1 unit.
|
AC current transducer |
|
|
|
|
|
FWAT |
|
|
|
|
|
Convert to DC signals in proportion to AC current in electric system. As insulated 2 outputs can be extracted, controlling/ monitoring are possible with 1 unit.
|
AC voltage transducer |
|
|
|
|
|
FWVT |
|
|
|
|
|
With tachogenerator mounted to generator, etc. as input and convert to DC signals in proportion to revolution speed(frequency) by insulating between input and output. As insulated 2 outputs can be extracted, controlling/ monitoring are possible with 1 unit.
|