OUTLINE
High quality/high reliability is achieved w/ high-performanced electronic
parts, running-in of individual part, electric running-in of product under
high-temperature environment.
Printed circuit board (B side) is cleaned after parts mounting and processed
in coating w/ high moisture resistance varnish and insulation resistance
of substrate surface is stabilized and insulation deterioration is prevented.
W/ output limiter circuit to limit the output to be 1.5 times of rated
value and protect equipment on output side even though excess input is
applied. |
catalog for plug-in transducer 2 outputs type |
catalog for all types of plug-in transducer 2 outputs type |
e_PLUG-IN-2 series_Rev0.pdf
SIZE:1,681KB
total page no.:22 |
type configuration/ specification/ outline drawing |
type configuration/ common specification/ outline drawing/ purchase specification |
e_PLUG-IN-2_kyoutuu_Rev0.pdf
SIZE:472KB
total page no.:7 |
Following catalog is the excerpt of plug-in transducer 2 outputs type catalog.
isolator |
|
WTP2- ( )( )( )( ) |
|
Convert to compatible signal among systems by amplifying various kinds
of DC signals. This product can be used for following purposes. Delivery
of insulated signals among power measuring system/ shutdown of noise/ prevention
of sneak in control circuit and direct transmission of output signal to
distant place.
current loop supply (distributor) |
|
WDTP2 -C7( )( )( ) , WSRDTP2 -C7( )( )( ) |
|
Supplying power source to 2-wire system transmitter, receiving DC4-20m
signal from transmitter and outputting proportional DC signal/ DC signal
proportional to square root.
frequency transducer |
|
WFTP2- ( )( )( )( )( ) |
|
Convert frequency in electric system to DC signals in proportion to input amount.
thermocouple transducer |
|
WHTP2- ( )( )( )( )( ) |
|
Insulating input / output and converting to DC signals in proportion to
temperature with thermoelectromotive force of various kinds of thermocouple
as input.
potentiometer transducer |
|
WRTP2- Z( )( )( ) |
|
By replacing mechanical angle and position displacement to resistance value
change of potentiometer as input and convert to DC signals in proportion
to displacement by insulation.
AC current transducer |
|
WAETP2- ( )( )( )( ) |
|
Convert AC current in electric system to DC signals in proportion to input
amount.
resistance temperature transducer |
|
WRHTP2- ( )( )( )( )( ) |
|
Insulating input/ output and converting to DC signals in proportion to
temperature with resistance value of 3-wire system resistance bulb as input.
AC voltage transducer |
|
WVETP2- ( )( )( )( ) |
|
Convert AC voltage in electric system to DC signals in proportion to input
amount.
constant voltage/ constant current output RMS value type.
|
|
|
|